01What is the panels-to-inverter ratio, and why?
✕Not stated
✓1.25 to 1.30, so the inverter works near its best for more of the day
02Which panel and inverter, on which datasheet?
✕A make “or equivalent”
✓Named in the offer, designed from their latest Indian datasheets
03Where does the inverter sit?
✕Wherever there is room, with long DC runs
✓Beside the panels, with the AC run to your nearest LT panel
04What size is each cable, and its voltage drop?
✕“As required”
✓On the drawing, every run checked
05Are string fuses needed, and what surge protection is fitted?
✕The same kit for every plant
✓Worked out for this plant from its currents
06How many earth pits, and why that many?
✕A round number
✓From your fault current and your soil
07Does the arrester reach the whole array?
✕A count, with no reach shown
✓Checked to its far corners
08Are the units guaranteed, at P50 or P90?
✕The panels only, or a P50 figure
✓Units at P90, in writing